/zoning-analysis-nyc — Zoning Envelope Analysis (New York City)

Analyze building envelope rules for any lot in New York City using the PLUTO database (NYC Open Data) and the NYC Zoning Resolution.

Workflow

Step 1: Parse Input

Accept one of the following identifiers:

  • Address + Borough/Zip — e.g., "123 Main St, Brooklyn 11201"
  • BBL — 10-digit Borough-Block-Lot (e.g., 3012340056 = Brooklyn, Block 1234, Lot 56)
  • BIN — Building Identification Number

Normalize to BBL format:

[borough 1 digit][block 5 digits][lot 4 digits]

Borough codes:

CodeBorough
1Manhattan
2Bronx
3Brooklyn
4Queens
5Staten Island

Step 2: Query PLUTO (tabular + polygon)

Fetch lot data from two NYC APIs in parallel:

2a. Tabular data (Socrata PLUTO)

Endpoint:

https://data.cityofnewyork.us/resource/64uk-42ks.json

Query by BBL:

https://data.cityofnewyork.us/resource/64uk-42ks.json?bbl=XXXXXXXXXX

Query by address (fallback):

https://data.cityofnewyork.us/resource/64uk-42ks.json?$where=address='123 MAIN STREET' AND zipcode='10001'

No authentication required for basic queries.

Read

zoning-rules/pluto-fields.md
for the full field reference.

Extract these key fields:

  • bbl
    — Borough-Block-Lot
  • address
    ,
    zipcode
    — street address
  • zonedist1
    through
    zonedist4
    — zoning district(s)
  • overlay1
    ,
    overlay2
    — commercial overlay districts
  • spdist1
    ,
    spdist2
    ,
    spdist3
    — special purpose districts
  • ltdheight
    — limited height district
  • splitzone
    — Y if lot is split across zones
  • lotarea
    — lot area in SF
  • bldgarea
    — total building area in SF
  • builtfar
    — as-built FAR
  • residfar
    — maximum residential FAR
  • commfar
    — maximum commercial FAR
  • facilfar
    — maximum community facility FAR
  • numfloors
    — existing number of floors
  • landuse
    — current land use category
  • zonemap
    — zoning map number
  • landmark
    — landmark designation
  • histdist
    — historic district name
  • borocode
    ,
    block
    ,
    lot
    — parsed BBL components

2b. Lot polygon (MapPLUTO ArcGIS Feature Service)

Endpoint:

https://a841-dotweb01.nyc.gov/arcgis/rest/services/GAZETTEER/MapPLUTO/MapServer/0/query

Query by BBL:

https://a841-dotweb01.nyc.gov/arcgis/rest/services/GAZETTEER/MapPLUTO/MapServer/0/query?where=BBL='XXXXXXXXXX'&outFields=BBL&f=json&outSR=4326

This returns the exact tax lot polygon in WGS84 (lat/lon). No authentication required.

Convert to local feet:

  1. Extract the
    features[0].geometry.rings[0]
    coordinate array (pairs of
    [lon, lat]
    )
  2. Compute the centroid latitude for the cos correction factor:
    cos(lat)
  3. Convert to local feet using:
    • x_ft = (lon - lon_min) × 111320 × cos(lat) × 3.28084
    • y_ft = (lat - lat_min) × 111320 × 3.28084
  4. Origin at the southernmost point (Y=0 at street/south side)
  5. Output a
    LOT_POLY
    array of
    [x, y]
    pairs in feet
  6. Verify the computed area against PLUTO's
    lotarea
    (expect ±5% due to projection)

Always use the real polygon for the 3D envelope viewer. Never fall back to a

lotfront × lotdepth
rectangle when polygon data is available.

If either query returns no results, inform the user and ask them to verify the address or BBL.

Step 3: Identify Zoning District

Map the

zonedist1
value to its district type:

PrefixTypeNormativa File
RResidential
zoning-rules/residential.md
CCommercial
zoning-rules/commercial.md
MManufacturing
zoning-rules/manufacturing.md

Check for:

  • Split zones (
    splitzone = Y
    ): Analyze each
    zonedist1
    zonedist4
    separately. Pro-rate FAR by estimated area in each zone if lot dimensions are available, otherwise present both sets of controls.
  • Contextual suffixes (A, B, D, X): If the district code ends in a letter suffix (e.g., R7A, C6-2A), also load
    zoning-rules/contextual-districts.md
    .
  • Commercial overlays (
    overlay1
    /
    overlay2
    ): If present (e.g., C1-4, C2-5), load
    zoning-rules/commercial.md
    for overlay rules.
  • Special districts (
    spdist1
    spdist3
    ): If present, load
    zoning-rules/special-districts.md
    .
  • Limited height (
    ltdheight
    ): Note the height cap.

State your district identification and reasoning clearly.

Step 4: Load Normativa

Read the relevant regulation files from the skill's

zoning-rules/
directory:

  1. Always read:
    zoning-rules/overview.md
    — system primer
  2. Primary district file: One of
    residential.md
    ,
    commercial.md
    , or
    manufacturing.md
  3. Conditionally read:
    • zoning-rules/contextual-districts.md
      — if district has A/B/D/X suffix
    • zoning-rules/special-districts.md
      — if
      spdist1
      spdist3
      are populated
    • zoning-rules/use-groups.md
      — for permitted use analysis
    • zoning-rules/parking.md
      — for parking requirements
    • zoning-rules/city-of-yes.md
      — for recent reform impacts

Step 5: Determine Bulk Controls

Calculate the building envelope for the lot:

  1. Floor Area Ratio (FAR):

    • Residential FAR (from
      residfar
      or district table)
    • Commercial FAR (from
      commfar
      or district table)
    • Community Facility FAR (from
      facilfar
      or district table)
    • Maximum zoning floor area = FAR × lot area
  2. Building Height:

    • Base height range (contextual districts)
    • Maximum building height
    • Sky exposure plane angle and setback distance
    • Limited height district cap (if applicable)
  3. Setbacks:

    • Front: initial setback distance and sky exposure plane
    • Side: narrow/wide street rules
    • Rear: standard 30 ft for residential, varies for commercial
    • Sky exposure plane: ratio and starting height
  4. Lot Coverage:

    • Maximum lot coverage percentage
    • Open space ratio (for non-contextual R districts)
  5. Yards:

    • Front yard requirements
    • Side yard requirements (corner lots, through lots)
    • Rear yard: typically 30 ft or 20% of lot depth

Apply contextual district rules when suffix is present — these override standard height/setback rules with mandatory streetwall, base height, and setback requirements.

Step 6: Check Overlays & Special Districts

Layer additional regulations on top of base district controls:

  1. Commercial overlays (C1-1 through C2-5 in residential districts):

    • Additional commercial FAR (typically 1.0 or 2.0)
    • Commercial use depth limit (typically 150 ft from street)
    • Permitted commercial uses (Use Groups 5–9 for C1, 5–14 for C2)
  2. Special purpose districts:

    • Modified bulk controls, use restrictions, design requirements
    • Check
      zoning-rules/special-districts.md
      for the specific district
  3. Inclusionary Housing:

    • Bonus FAR available in designated areas
    • Mandatory Inclusionary Housing (MIH) areas: must provide affordable units for bonus
  4. Landmark / Historic District:

    • If
      landmark
      or
      histdist
      is populated, note that Landmarks Preservation Commission (LPC) review is required
    • Bulk controls still apply but modifications may need LPC approval
  5. City of Yes reforms:

    • Check
      zoning-rules/city-of-yes.md
      for applicable changes
    • Universal Affordability Preference (UAP): +20% FAR for affordable housing
    • Town Center Zoning: ground-floor commercial in residential districts near transit
    • Parking: most mandates eliminated citywide

Step 7: Present Analysis

Use the output format below to present a structured, comprehensive analysis.

Step 8: Save Report

Write the analysis to a markdown file in the current working directory:

  • Filename:
    zoning-analysis-[address-slug].md
  • Example:
    zoning-analysis-123-main-st-brooklyn.md

Output Format

# Zoning Analysis — [Address], [Borough]

## Lot Summary
| Parameter | Value |
|-----------|-------|
| BBL | X-XXXXX-XXXX |
| Address | ... |
| Borough | ... |
| Lot Area | ... SF |
| Current Building Area | ... SF |
| Current FAR (built) | ... |
| Current Use | ... |
| Zoning Map | ... |

## Zoning Classification
| Parameter | Value |
|-----------|-------|
| Primary District | ... |
| Secondary District(s) | ... (or None) |
| Commercial Overlay | ... (or None) |
| Special District | ... (or None) |
| Limited Height | ... (or None) |
| Contextual | Yes/No |
| Split Zone | Yes/No |
| Landmark | ... (or None) |
| Historic District | ... (or None) |

## Bulk Parameters

### Floor Area
| Use | Max FAR | Max Floor Area (SF) |
|-----|---------|---------------------|
| Residential | ... | ... |
| Commercial | ... | ... |
| Community Facility | ... | ... |

### Height & Setback
| Parameter | Value |
|-----------|-------|
| Max Building Height | ... ft |
| Base Height (min–max) | ... ft (contextual only) |
| Sky Exposure Plane | starts at ... ft, ratio .../1 |
| Street Wall | required/not required |

### Yards & Coverage
| Parameter | Value |
|-----------|-------|
| Front Yard | ... ft |
| Rear Yard | ... ft |
| Side Yards | ... |
| Max Lot Coverage | ...% |
| Open Space Ratio | ... (if applicable) |

## Permitted Uses
Key permitted uses by Use Group for this district. Highlight the most relevant:
- Residential: ...
- Commercial: ...
- Community Facility: ...
- Manufacturing: ... (if applicable)

## Parking Requirements
Based on current rules (post-City of Yes where applicable):
| Use | Requirement |
|-----|-------------|
| Residential | ... |
| Commercial | ... |
| Other | ... |

## Bonuses & Incentives
- Inclusionary Housing bonus: ...
- UAP (City of Yes): ...
- Other applicable bonuses: ...

## Restrictions & Special Conditions
- Landmark/LPC review: ...
- Special district requirements: ...
- Environmental: ...
- Other: ...

## Development Potential
| Scenario | FAR | Floor Area (SF) | Est. Floors |
|----------|-----|------------------|-------------|
| As-of-right residential | ... | ... | ... |
| As-of-right commercial | ... | ... | ... |
| With IH bonus | ... | ... | ... |
| With UAP bonus | ... | ... | ... |

## Buildable Envelope

### Plan View
ASCII diagram showing the lot boundary with setbacks and buildable zone. Orient with the primary street frontage at the bottom. Label dimensions, setback distances, and buildable area. Use PLUTO lot dimensions (lotfront, lotdepth) where available.

Example:
                ← 170 ft →
     ┌────────────────────────────┐
     │        20 ft rear yard     │  ↑
     │  ┌──────────────────────┐  │  |
     │  │                      │  │  |
     │  │   BUILDABLE ZONE     │  │  130 ft
     │  │   ~150 ft × 170 ft   │  │  |
     │  │                      │  │  |
     │  │                      │  │  |
     │  └──────────────────────┘  │  ↓
     └────────────────────────────┘
          HUDSON ST (wide street)
          ← no front setback →

### Section View
ASCII cross-section showing the height and setback envelope from street level. Include base height, setback, sky exposure plane, and maximum height. For contextual districts, show the mandatory streetwall height range.

Example:

290 ft ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ max height │ ╱ │ ╱ sky exposure │ ╱ plane (5.6:1) │ ╱ 85 ft ├──────┤ ← setback line │ │ │ │ base / streetwall │ │ (60–85 ft) │ │ ───────┴──────┴──────────────── street HUDSON ST (wide)


Adapt both diagrams to the specific lot. Use actual dimensions and controls from the analysis. If the lot is irregular or split-zone, note the complexity and simplify where needed.

## Envelope Data

Machine-readable data for `/zoning-envelope`. Include the exact lot polygon from Step 2b (MapPLUTO ArcGIS) converted to local feet, plus all computed envelope parameters.

```json
{
  "lot_poly": [[x, y], ...],
  "unit": "ft",
  "setbacks": { "front": 0, "rear": 20, "lateral1": 0, "lateral2": 0 },
  "volumes": [
    { "type": "base", "inset": 20, "h_bottom": 0, "h_top": 85, "label": "base (streetwall)" },
    { "type": "tower", "inset": 10, "h_bottom": 85, "h_top": 290, "label": "tower" }
  ],
  "height_cap": 290,
  "info": { "title": "...", "zone": "...", "id": "BBL ...", "area": "... SF" },
  "stats": { "Commercial FAR": "10.0", "Max Floor Area": "218,620 SF", ... }
}

Adapt the

volumes
array to the district type:

  • Height-factor: One base volume (0 to sky start) + one tapered volume or approximation
  • Contextual: Base/streetwall volume + tower volume with deeper inset
  • With front yard: Add front setback to
    setbacks

To generate an interactive 3D viewer from this data, run:

/zoning-envelope path/to/this-report.md

Caveats

  • This analysis is based on publicly available zoning data (PLUTO) and general Zoning Resolution rules
  • Always verify with NYC Department of City Planning and ZoLa (zola.planning.nyc.gov)
  • Special permits, variances, and BSA actions are not reflected in PLUTO data
  • City of Yes provisions are being phased in — confirm effective dates for specific provisions
  • Site-specific conditions (flood zones, coastal erosion, environmental restrictions) require additional review
  • This is not a substitute for professional zoning analysis or legal advice

## Notes

- The NYC Zoning Resolution is maintained by the Department of City Planning
- PLUTO data is updated quarterly — verify currency for critical decisions
- Contextual districts (with letter suffixes) have mandatory streetwall and height rules that override standard bulk controls
- City of Yes for Housing Opportunity was adopted December 2024 — some provisions phase in over time
- When in doubt about district classification or applicable rules, always ask the user
- For split-zone lots, analyze each zone separately and note the complexity
- ZoLa (zola.planning.nyc.gov) is the authoritative visual reference — recommend users verify there